Nonpowered Valves » Globe Valves (7,355 Items)
Page 6 of 148
2038
SKU 4820001710575
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Connection Style: Plain, optional en (pipe) all ends
2000-1
SKU 4820001721828
- Thread Direction: Right-hand all ends
- Offset Distance: 0.281 inches
- Flow Control Device: Needle
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Integral
7640W
SKU 4820001742542
- Pipe Size Accommodated: 1.500 inches 1ST end
- Flow Control Device: Disk
- Bonnet Type: Outside screw-yoke
- Bonnet Attachment Method: Integral
- Maximum Operating Temp: 1150.0 degrees fahrenheit single response
7640W
SKU 4820001742587
- Connection Type: Butt weld tube 1ST end
- Outside Diameter Tube Accommodated: 0.500 inches 1ST end
- Material: Steel body
8130S
SKU 4820001742595
- Pipe Size Accommodated: 0.375 inches 1ST end
- Thread Direction: Right-hand 1ST end
- Flow Control Device: Stem or disk
- Bonnet Type: Outside screw-yoke
- Bonnet Attachment Method: Bolted
T9424T1-4CC
SKU 4820001756263
- Thread Class: 2A all ends
- Thread Direction: Right-hand all ends
- Flow Control Device: Stem or disk
- Bonnet Type: Inside spring
- Bonnet Attachment Method: Threaded
Q4600-80
SKU 4820001757155
- Thread Class: 2B all ends
- Thread Direction: Right-hand all ends
- Flow Control Device: Needle
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Integral
818-0-3-4KT
SKU 4820001757701
- Thread Class: 3B 1ST end
- Thread Direction: Right-hand 1ST end
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Connection Style: Gasket sea (boss) 1ST end
820-2179382-3
SKU 4820001764812
- Criticality Code Justification: Zzzy
820-2179382-4
SKU 4820001764815
- Criticality Code Justification: Zzzy
820-2179382-11
SKU 4820001764816
- Criticality Code Justification: Zzzy
820-2179382-6
SKU 4820001764817
- Criticality Code Justification: Zzzy
820-2179382-1
SKU 4820001764822
- Criticality Code Justification: Zzzy
820-2179382-7
SKU 4820001764833
- Criticality Code Justification: Zzzy
0131
SKU 4820001768974
- Flow Control Device: Disk
- Bonnet Type: Outside screw-yoke
- Bonnet Attachment Method: Bolted
- Renewable Seat Ring Type: Threaded
- Bolt Hole Quantity: 4 1ST end
3033
SKU 4820001768976
- Pipe Size Accommodated: 6.000 inches 1ST end
- Connection Type: Butt weld pipe 1ST end
- Material: Steel body
820-2178991-10
SKU 4820001775829
- Criticality Code Justification: Zzzy
820-2178991-1
SKU 4820001775830
- Criticality Code Justification: Zzzy
820-2178991-11
SKU 4820001775834
- Criticality Code Justification: Zzzy
820-2178660
SKU 4820001776165
- Criticality Code Justification: Zzzy
820-2178660-14
SKU 4820001776190
- Criticality Code Justification: Zzzy
1801347
SKU 4820001815899
- Special Features: End connection quantity: 2;
W01-3074B-02TS 33311-30REVG
SKU 4820001819443
- Pipe Size Accommodated: 0.250 inches all ends
- Flow Control Device: Disk
- Bonnet Type: Outside screw-yoke
- Bonnet Attachment Method: Bolted
- Maximum Operating Temp: 775.0 degrees fahrenheit single response
W02-3074B-02TS/33311-30K/8820579
SKU 4820001819444
- Pipe Size Accommodated: 0.375 inches all ends
- Flow Control Device: Disk
- Bonnet Type: Outside screw-yoke
- Bonnet Attachment Method: Bolted
- Maximum Operating Temp: 775.0 degrees fahrenheit single response
B-512-1-B1
SKU 4820001819445
18S-FS-2 1IN
SKU 4820001819446
81551-01
SKU 4820001819447
- Pipe Size Accommodated: 1.250 inches all ends
- Flow Control Device: Disk
- Bonnet Type: Outside screw-yoke
- Bonnet Attachment Method: Bolted
- Maximum Operating Temp: 775.0 degrees fahrenheit single response
W07-3074B-02TS 333-11-30REV P
SKU 4820001819448
115CB1 2IN
SKU 4820001819449
803-2177525-S311(SPCLN)
SKU 4820001819459
- Criticality Code Justification: Zzzy
803-2177525-S511(SPCLNOLD)
SKU 4820001819465
- Criticality Code Justification: Zzzy
803-2177525-S811(SPCLN)
SKU 4820001819466
- Criticality Code Justification: Zzzy
750-1-4
SKU 4820001836773
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Maximum Operating Temp: 400.0 degrees fahrenheit single response
SC138WS
SKU 4820001836991
- Pipe Size Accommodated: 0.500 inches all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
7530W
SKU 4820001849056
- Pipe Size Accommodated: 2.500 inches 1ST end
- Flow Control Device: Disk
- Bonnet Type: Outside screw-yoke
- Bonnet Attachment Method: Bolted
- Maximum Operating Temp: 1020.0 degrees fahrenheit single response
95104-V2
SKU 4820001849186
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
803-4384536-22AXAF
SKU 4820001856844
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
803-4384536-52B1AF
SKU 4820001856846
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
803-4384536-62B
SKU 4820001856847
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
803-4384536-72B1AF
SKU 4820001856848
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
M65545
SKU 4820001859857
803-4384536-61AXAF
SKU 4820001863541
- Pipe Size Accommodated: 1.250 inches all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
803-4384536-31AXAF NON-MAG
SKU 4820001863820
- Pipe Size Accommodated: 0.500 inches all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
803-4384536-41AXAF
SKU 4820001863821
- Pipe Size Accommodated: 0.750 inches all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
24024696
SKU 4820001863824
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
803-4384536-62A AF
SKU 4820001863826
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
803-4384536-32B1AF
SKU 4820001863828
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
803-4384536-82B22
SKU 4820001863831
- Thread Direction: Right-hand all ends
- Flow Control Device: Disk
- Bonnet Type: Inside screw
- Bonnet Attachment Method: Threaded
- Renewable Seat Ring Type: Threaded
1801610-2
SKU 4820001874400
- Flow Control Device: Disk
- Bonnet Type: Packing retaining
- Connection Style: Plain (tube) all ends
- Valve Operation Method: Manual
- Connection Type: Unthreaded internal tube all ends
803-2177525-C6A1AF
SKU 4820001876144
- Flow Control Device: Disk
- Bonnet Type: Outside screw-yoke
- Bonnet Attachment Method: Bolted
- Maximum Operating Temp: 775.0 degrees fahrenheit single response
- Connection Style: Socket (tube) 1ST end
Aerospace Hardware Guarantee
Genuine Manufacturers Parts
100% Product Inspection
7 year Sales Record Retention
Fast On-Time Delivery
HAZMAT Certified
Global Shipping
&nbps;
Popular Nonpowered Valves
- 45-4414 - Valve Locknut
- 3463-3IN - Gate Valve
- 116A3-8 - Check Valve
- 040058-01 - Expansion Valve
- 304656C1 - Plug Cock
- 7796SP5 - Globe Valve
- 050-24190-7 - Directional Con Sleeve And Slide
- C5-45-2598 - Foot Valve
- C0207-2 - Safety Relief Valve