Part Number 561A017-3 S Electrical Insulation Sleeving
SKU: 5970009982229561A0173 S Electrical Insulation Sleeving Datasheet
Reliability Indicator:
Not established
Tempurature Rating:
-55.0 degrees celsius
Environmental Protection:
Corrosion resistant and flame resistant and mildew resistant and solvent resistant and water resistant
Main Body Inside Diameter:
0.490 inches after unrestricted recovery
Main Body Inside Diameter:
1.620 inches as supplied
First Branch Inside Diameter:
0.490 inches after unrestricted recovery
First Branch Inside Diameter:
1.060 inches as supplied
Second Branch Inside Diameter:
0.490 inches after unrestricted recovery
Second Branch Inside Diameter:
1.060 inches as supplied
Third Branch Inside Diameter:
0.490 inches after unrestricted recovery
Third Branch Inside Diameter:
1.060 inches as supplied
Fourth Branch Inside Diameter:
0.490 inches after unrestricted recovery
Fourth Branch Inside Diameter:
1.060 inches as supplied
Distance From Intersecting Centerline Of Main Body To End Of Second Branch:
3.960 inches as supplied
Distance From Intersecting Centerline Of Main Body To End Of First Branch:
3.580 inches after unrestricted recovery
Main Body Wall Thickness:
0.100 inches as supplied
Main Body Wall Thickness:
0.100 inches after unrestricted recovery
First Branch Wall Thickness:
0.100 inches as supplied
First Branch Wall Thickness:
0.100 inches after unrestricted recovery
Second Branch Wall Thickness:
0.100 inches as supplied
Second Branch Wall Thickness:
0.100 inches after unrestricted recovery
Third Branch Wall Thickness:
0.100 inches as supplied
Third Branch Wall Thickness:
0.100 inches after unrestricted recovery
Fourth Branch Wall Thickness:
0.100 inches as supplied
Fourth Branch Wall Thickness:
0.100 inches after unrestricted recovery
Distance From Edge Of Main Body To Intersecting Centerlines:
3.620 inches after unrestricted recovery
Angle Between Main Body And First Branch Centerlines In Deg:
10.0 as supplied
Angle Between Main Body And First Branch Centerlines In Deg:
45.0 after unrestricted recovery
Angle Between Main Body And Second Branch Centerlines In Deg:
15.0 after unrestricted recovery
Angle Between Main Body And Second Branch Centerlines In Deg:
10.0 as supplied
Min. Tensile Strength (psi):
1500 pounds per square inch
Flexibility:
Semirigid
Color:
Black
Material:
Plastic, polyolefin, RT-301, raychem corp
Style Designator:
TRANSITION-1 to 4 cables
Dielectric Material Voltage Rating Per Unit Thickness:
200.0 volts per military /0.001 inch/
Manufacturer Cage:
06090
Trade Information:
- Schedule B: 8546900000
- SITC: 77324
- End Use: Electric apparatus
- NAICS: 326199
- USDA: 1
Electrical insulators, nesoi
Aerospace Hardware Guarantee
Genuine Manufacturers Parts
100% Product Inspection
7 year Sales Record Retention
Fast On-Time Delivery
HAZMAT Certified
Global Shipping