Aerospace Hardware Store

Aerospace

Hardware

5340-00-866-1237

Loop Clamp

Specifications, compliance details, and sourcing options for this NSN. Request a quote to confirm availability, pricing, and lead time.

Request for Quote

Send us a request for quote using the form below. Our team will promptly provide you with the latest pricing and availability details.

AS9120 ISO9001 Aviation Suppliers Association Global Shipping

Partes destacadas

209-373-001-101
4810-01-256-7209
Solenoid Valve
209-373-002-101
4820-01-256-7207
Check Valve
209-373-003
4710-01-256-7675
Branched Metal Tube Assembly
209-373-003-103
4710-01-256-7675
Branched Metal Tube Assembly
209-375-059-101
5342-01-309-5105
Weapon System Resilient Mount
209-376-001
4820-01-182-6700
Check Valve
209-376-001-101
4820-01-182-6700
Check Valve
209-376-023
4820-01-300-9233
Relief Balanced Valve

Need Assistance?

Our catalog is extensive, but we understand that sometimes specific needs might not be immediately available. If you could not find the exact products you were searching for, we are here to help!

Contact us directly, and our team will assist you in finding the perfect solution for your requirements.

Contáctenos

Certified Supplier

Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.

  • Genuine Manufacturers Parts
  • 100% Product Inspection
  • 7 Year Sales Record Retention
  • Fast On-Time Delivery
  • Certificación HAZMAT
  • Global Shipping

Official Item Classification

Nombre
Loop Clamp
(NSN) Número de stock nacional
5340-00-866-1237
(FSG) Grupo de suministro federal
53 Hardware and Abrasives
(FSC) Clasificación Federal de Suministros
5340 Ferretería Comercial
(INC) Código de nombre del artículo
17532
(FIIG) Guía Federal de Identificación de Artículos
A12700
Fecha
01/01/1962 (hace 64 años)

0.819 inches nominal distance from loop center to tongue end, 0.500 inches nominal overall width, 0.562 inches nominal loop inside diameter, 0.045 inches minimum and 0.075 inches maximum material thickness, 0.538 inches minimum and 0.622 inches maximum center to center distance between loop and mounting hole

Specs & Compatibility

Anchura total

0.500 inches nominal

Espesor del material

0.045 inches minimum and 0.075 inches maximum

Distancia de centro a centro entre el bucle y el orificio de montaje

0.538 inches minimum and 0.622 inches maximum

Distancia desde el centro del bucle hasta el extremo de la lengüeta

0.819 inches nominal

Diámetro interior del bucle

0.562 inches nominal

Material

plastic polyamide (nylon) band

Material, Documento Y Clasificación

mil-p-17091,ty 1 mil spec single material response band

Designador de estilo

single loop

Regulatory Compliance

Precious Metals Indicator
U

Precious metal content is unknown

Criticality Code
X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Hazardous Metals Indicator
P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Pseudo Item Name Code

0017532

Related Hardware Products

Número de Parte Descripción
710876-009 Loop Clamp
MS39014-9 Loop Clamp

Preguntas frecuentes

What is the FSCG of the NSN 5340-00-866-1237?
The FSCG of the NSN 5340-00-866-1237 is 5340
Does NSN 5340-00-866-1237 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5340-00-866-1237 contain precious materials?
Precious metal content is unknown
Does NSN 5340-00-866-1237 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5340-00-866-1237 was assigned to the Federal Catalog?
It was assigned hace 64 años, on Mon, Jan 1, 1962