203-059-0005 Synchro Clamp
5340-00-604-9656
Specifications, compliance details, and sourcing options for this NSN. Request a quote to confirm availability, pricing, and lead time.
Request for Quote
Send us a request for quote using the form below. Our team will promptly provide you with the latest pricing and availability details.
Partes destacadas
Need Assistance?
Our catalog is extensive, but we understand that sometimes specific needs might not be immediately available. If you could not find the exact products you were searching for, we are here to help!
Contact us directly, and our team will assist you in finding the perfect solution for your requirements.
ContáctenosCertified Supplier
Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.
- Genuine Manufacturers Parts
- 100% Product Inspection
- 7 Year Sales Record Retention
- Fast On-Time Delivery
- Certificación HAZMAT
- Global Shipping
Official Item Classification
- Nombre
- Synchro Clamp
- Número de Parte
- 203-059-0005
- (NSN) Número de stock nacional
- 5340-00-604-9656
- (FSG) Grupo de suministro federal
- 53 Hardware and Abrasives
- (FSC) Clasificación Federal de Suministros
- 5340 Ferretería Comercial
- (INC) Código de nombre del artículo
- 40268
- (FIIG) Guía Federal de Identificación de Artículos
- A09900
- Fecha
- 01/01/1961 (hace 65 años)
0.125 inches minimum and 0.140 inches maximum hole diameter, locknut furnished items, 0.328 inches nominal length, 0.113 inches minimum and 0.118 inches maximum height, 0.213 inches minimum and 0.223 inches maximum width
Specs & Compatibility
0.125 inches minimum and 0.140 inches maximum
locknut
0.213 inches minimum and 0.223 inches maximum
0.328 inches nominal
0.113 inches minimum and 0.118 inches maximum
steel comp 416
qq-s-764,cond h fed spec single material response
passivate
mil-f-14072,finish e3 mil spec single treatment response
Replacement For
| Número de Parte | Descripción | |
|---|---|---|
| 5340-00-981-0640 | No Name Available | 02/01/1981 |
Regulatory Compliance
Precious metal content is unknown
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
0040268
Related Hardware Products
| Número de Parte | Descripción |
|---|---|
| 203-059-0005 | Synchro Clamp |
| 203-059-1 | Synchro Clamp |
| 5340006049656 | Synchro Clamp |
| 8437429 | Synchro Clamp |