Aerospace Hardware Store

Aerospace

Hardware

EV136AT47FMO Solenoid Valve

4810-01-321-5367

Specifications, compliance details, and sourcing options for this NSN. Request a quote to confirm availability, pricing, and lead time.

Request for Quote

Send us a request for quote using the form below. Our team will promptly provide you with the latest pricing and availability details.

AS9120 ISO9001 Aviation Suppliers Association Global Shipping

Featured Parts

91290A385
5305-01-691-6856
Machine Screw
91290A416
5305-01-620-5362
Socket Head Cap Screw
91290A432
5305-01-465-6422
Socket Head Cap Screw
91290A434
5305-01-491-0830
Socket Head Cap Screw
91290A438
5305-01-559-0887
Socket Head Cap Screw
91290A442
5305-01-558-9957
Socket Head Cap Screw
91290A446
5305-01-621-0319
Socket Head Cap Screw
91290A456
5305-01-612-6255
Socket Head Cap Screw

Need Assistance?

Our catalog is extensive, but we understand that sometimes specific needs might not be immediately available. If you could not find the exact products you were searching for, we are here to help!

Contact us directly, and our team will assist you in finding the perfect solution for your requirements.

Contact Us

Certified Supplier

Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.

  • Genuine Manufacturers Parts
  • 100% Product Inspection
  • 7 Year Sales Record Retention
  • Fast On-Time Delivery
  • HAZMAT Certified
  • Global Shipping

Official Item Classification

Name
Solenoid Valve
Part Number
EV136AT47FMO
(NSN) National Stock Number
4810-01-321-5367
(FSG) Federal Supply Group
48 Valves
(FSC) Federal Supply Classification
4810 Powered Valves
(INC) Item Name Code
10998
(FIIG) Federal Item Identification Guide
A046B0
Date
06/20/1990 (36 years ago)

disk flow control device, 6 all ends bolt hole quantity, closed flow control device normal operation position, solenoid valve operation method, 212.0 fahrenheit single response maximum operating temp

Specs & Compatibility

Flow Control Device

disk

Flow Control Device Normal Operation Position

closed

Bolt Hole Quantity

6 all ends

Maximum Operating Temp

212.0 fahrenheit single response

Valve Operation Method

solenoid

Flange Shape

round with holes all ends

Connection Type

flange all ends

Mounting Position

vertical

Valve Size

2.000 inches

Voltage In Volts And Current Type

480.0 ac

Nominal Outside Diameter

5.562 inches all ends

Face To Face Distance

9.500 inches

Nominal Thickness

0.438 inches all ends

Bolt Hole Nominal Diameter

0.562 inches all ends

Bolt Circle Nominal Diameter

4.438 inches all ends

Flange Face Design

plain all ends

Frequency In Hertz

60.0

Material

plastic polytetrafluoroethylene flow control device

Style Designator

straight thru flanged ends

Regulatory Compliance

Precious Metals Indicator
A

Item does not contain precious metal.

Criticality Code
X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Hazardous Metals Indicator
N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Pseudo Item Name Code

0010998

Related Hardware Products

Part Number Description
600-83 Solenoid Valve
EV136AT47FMO Solenoid Valve

Frequently Asked Questions

What is the FSCG of the NSN 4810-01-321-5367?
The FSCG of the NSN 4810-01-321-5367 is 4810
Does the NSN 4810-01-321-5367 have a Schedule B code assigned?
Yes, the Schedule B code is 8481809005
Does NSN 4810-01-321-5367 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 4810-01-321-5367 contain precious materials?
Item does not contain precious metal.
Does NSN 4810-01-321-5367 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 4810-01-321-5367 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Wed, Jun 20, 1990