Aerospace Hardware Store

Aerospace

Hardware

4820-01-269-9491

Globe Valve

Specifications, compliance details, and sourcing options for this NSN. Request a quote to confirm availability, pricing, and lead time.

Request for Quote

Send us a request for quote using the form below. Our team will promptly provide you with the latest pricing and availability details.

AS9120 ISO9001 Aviation Suppliers Association Global Shipping

Featured Parts

BATH-P/N-0713-1
4820-01-356-4654
Fluid Valve Stem
BATH-P/N-0713-6
4820-01-356-8626
Valve Disk
BATH-P/N-0713-7
4820-01-363-2271
Valve Seat
BATT702
5330-01-437-0917
Special Purpo Thermal Insulation
BAU794
5340-01-648-3663
Electronic Equipmen Hardware Kit
BAUER CAT PG C-3 ITEM 14
5331-01-486-0624
O-Ring
BAV020
4810-01-708-4025
Solenoid Valve
BAV050SA
4810-01-554-7806
Solenoid Valve

Need Assistance?

Our catalog is extensive, but we understand that sometimes specific needs might not be immediately available. If you could not find the exact products you were searching for, we are here to help!

Contact us directly, and our team will assist you in finding the perfect solution for your requirements.

Contact Us

Certified Supplier

Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.

  • Genuine Manufacturers Parts
  • 100% Product Inspection
  • 7 Year Sales Record Retention
  • Fast On-Time Delivery
  • HAZMAT Certified
  • Global Shipping

Official Item Classification

Name
Globe Valve
(NSN) National Stock Number
4820-01-269-9491
(FSG) Federal Supply Group
48 Valves
(FSC) Federal Supply Classification
4820 Nonpowered Valves
(INC) Item Name Code
05485
(FIIG) Federal Item Identification Guide
A046B0
Date
12/24/1987 (38 years ago)

poppet flow control device, 8 all ends bolt hole quantity, bolted bonnet attachment method, 200.0 fahrenheit single response maximum operating temp, inside screw bonnet type

Specs & Compatibility

Flow Control Device

poppet

Bonnet Type

inside screw

Bonnet Attachment Method

bolted

Bolt Hole Quantity

8 all ends

Maximum Operating Temp

200.0 fahrenheit single response

Valve Operation Method

manual

Flange Shape

round with holes all ends

Connection Type

flange all ends

Valve Size

2.000 inches

Maximum Operating Pressure

600.0 pounds per square inch single response

Nominal Outside Diameter

6.500 inches all ends

Face To Face Distance

11.560 inches

Nominal Thickness

1.000 inches all ends

Bolt Hole Nominal Diameter

0.750 inches all ends

Bolt Circle Nominal Diameter

5.000 inches all ends

Flange Face Design

raised straight all ends

Raised Face Nominal Height

0.062 inches

Raised Face Nominal Diameter

3.628 inches

Material

steel corrosion resisting overall

Style Designator

straight thru flanged ends

Regulatory Compliance

Precious Metals Indicator
A

Item does not contain precious metal.

Criticality Code
X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Hazardous Metals Indicator
N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Pseudo Item Name Code

0005485

Related Hardware Products

Part Number Description
283389-0002 SPV82B-5 Globe Valve
SPV82B-5 283389-0002 Globe Valve

Frequently Asked Questions

What is the FSCG of the NSN 4820-01-269-9491?
The FSCG of the NSN 4820-01-269-9491 is 4820
Does the NSN 4820-01-269-9491 have a Schedule B code assigned?
Yes, the Schedule B code is 8481803060
Does NSN 4820-01-269-9491 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 4820-01-269-9491 contain precious materials?
Item does not contain precious metal.
Does NSN 4820-01-269-9491 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 4820-01-269-9491 was assigned to the Federal Catalog?
It was assigned 38 years ago, on Thu, Dec 24, 1987