Aerospace Hardware Store

Aerospace

Hardware

MS21103-26 Loop Clamp

5340-01-059-2448

Specifications, compliance details, and sourcing options for this NSN. Request a quote to confirm availability, pricing, and lead time.

Request for Quote

Send us a request for quote using the form below. Our team will promptly provide you with the latest pricing and availability details.

AS9120 ISO9001 Aviation Suppliers Association Global Shipping

Featured Parts

19-80-0808
5342-01-093-0548
Grooved Clamp Coupling
19-80-0994
2040-01-087-7465
Duct Silencer
19-80-1119A
2040-01-090-4401
Ventilatory Cover
19-80-1376
5342-01-093-0549
Grooved Clamp Coupling
19-80-1446
4730-01-184-0518
Flange to Flang Straight Adapter
19-80-1446MA1A
4730-01-184-0518
Flange to Flang Straight Adapter
19-80-1503
2040-01-086-2541
Deck Link Kit
19-80-1504
2040-01-086-2533
Deck Mounting Kit

Need Assistance?

Our catalog is extensive, but we understand that sometimes specific needs might not be immediately available. If you could not find the exact products you were searching for, we are here to help!

Contact us directly, and our team will assist you in finding the perfect solution for your requirements.

Contact Us

Certified Supplier

Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.

  • Genuine Manufacturers Parts
  • 100% Product Inspection
  • 7 Year Sales Record Retention
  • Fast On-Time Delivery
  • HAZMAT Certified
  • Global Shipping

Official Item Classification

Name
Loop Clamp
Part Number
MS21103-26
(NSN) National Stock Number
5340-01-059-2448
(FSG) Federal Supply Group
53 Hardware and Abrasives
(FSC) Federal Supply Classification
5340 Commercial Hardware
(INC) Item Name Code
17532
(FIIG) Federal Item Identification Guide
A12700
Date
04/08/1978 (48 years ago)

0.204 inches nominal diameter, 0.028 inches minimum and 0.036 inches maximum material thickness, round, unthreaded tongue hole type, 1.217 inches nominal center to center distance between loop and mounting hole, 0.500 inches nominal overall width

Specs & Compatibility

Tongue Hole Type

round, unthreaded

Overall Width

0.500 inches nominal

Diameter

0.204 inches nominal

Material Thickness

0.028 inches minimum and 0.036 inches maximum

Center To Center Distance Between Loop And Mounting Hole

1.217 inches nominal

Distance From Loop Center To Tongue End

1.435 inches nominal

Loop Inside Diameter

1.625 inches nominal

Material

steel comp 321 or steel comp 348 band

Material Document And Classification

mil-s-6721 mil spec all material responses band

Surface Treatment

passivate band

Surface Treatment Document And Classification

qq-p-35 fed spec single treatment response band

Style Designator

single loop

Replacement For

Part Number Description
5340-00-151-5958 No Name Available 11/01/1985

Regulatory Compliance

Precious Metals Indicator
U

Precious metal content is unknown

Criticality Code
X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Hazardous Metals Indicator
P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Pseudo Item Name Code

0017532

Related Hardware Products

Part Number Description
AS5587C26 Loop Clamp
MS21103-26 Loop Clamp

Frequently Asked Questions

What is the FSCG of the NSN 5340-01-059-2448?
The FSCG of the NSN 5340-01-059-2448 is 5340
Does the NSN 5340-01-059-2448 have a Schedule B code assigned?
Yes, the Schedule B code is 7326190000
Does NSN 5340-01-059-2448 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5340-01-059-2448 contain precious materials?
Precious metal content is unknown
Does NSN 5340-01-059-2448 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5340-01-059-2448 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Sat, Apr 8, 1978