Aerospace Hardware Store

Aerospace

Hardware

5320-00-395-6512

Tubular Rivet

Specifications, compliance details, and sourcing options for this NSN. Request a quote to confirm availability, pricing, and lead time.

Request for Quote

Send us a request for quote using the form below. Our team will promptly provide you with the latest pricing and availability details.

AS9120 ISO9001 Aviation Suppliers Association Global Shipping

Προτεινόμενα μέρη

114118.687-SS-12
5305-01-452-3578
Machine Screw
114118.688SSG12
5305-01-669-7637
Socket Head Cap Screw
114118-750SSGMOD1-31B
5305-01-656-0480
Machine Screw
11411828P
5360-00-298-2848
Compression Helical Spring
114119
5310-00-171-8882
Flat Washer
11412
5365-00-391-8320
Machine Thread Plug
11412-1
5365-00-391-8320
Machine Thread Plug
114120-.325-SS-12
5305-01-662-7592
Panel Screw Assembly

Need Assistance?

Our catalog is extensive, but we understand that sometimes specific needs might not be immediately available. If you could not find the exact products you were searching for, we are here to help!

Contact us directly, and our team will assist you in finding the perfect solution for your requirements.

Επικοινωνήστε μαζί μας

Certified Supplier

Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.

  • Genuine Manufacturers Parts
  • 100% Product Inspection
  • 7 Year Sales Record Retention
  • Fast On-Time Delivery
  • Πιστοποιημένο για επικίνδυνα υλικά (HAZMAT)
  • Global Shipping

Official Item Classification

Ονομα
Tubular Rivet
(NSN) Εθνικός αριθμός αποθέματος
5320-00-395-6512
(FSG) Ομοσπονδιακή ομάδα εφοδιασμού
53 Hardware and Abrasives
(FSC) Ομοσπονδιακή Ταξινόμηση Εφοδιασμού
5320 Κουβέρτες
(INC) Κωδικός ονόματος αντικειμένου
00863
(FIIG) Οδηγός Ομοσπονδιακής Αναγνώρισης Αντικειμένων
A040A0
Ημερομηνία
04/12/1974 (πριν 52 χρόνια)

0.100 inches minimum and 0.107 inches maximum hole diameter, 0.141 inches minimum and 0.146 inches maximum shank diameter, 0.035 inches minimum and 0.045 inches maximum head height, 0.151 inches minimum and 0.161 inches maximum fastener length, oval/truss head style

Specs & Compatibility

Μήκος συνδετήρα

0.151 inches minimum and 0.161 inches maximum

Στυλ κεφαλιού

oval/truss

Ύψος κεφαλής

0.035 inches minimum and 0.045 inches maximum

Διάμετρος τρύπας

0.100 inches minimum and 0.107 inches maximum

Διάμετρος στελέχους

0.141 inches minimum and 0.146 inches maximum

Στυλ στελέχους

tubular

Κύρια διάμετρος κεφαλής

0.229 inches minimum and 0.239 inches maximum

Βάθος τρύπας

0.121 inches minimum and 0.131 inches maximum

Δύναμη διάτμησης

24000 double pounds per square inch

Κατεργασία με θερμοκρασία

h-32 strain hardened overall

Υλικό

aluminum alloy 5056 overall

Μη οριστικά δεδομένα προδιαγραφών/τυποποιημένων δεδομένων

12 type and 3 class and b grade

Regulatory Compliance

Precious Metals Indicator
U

Precious metal content is unknown

Criticality Code
X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Hazardous Metals Indicator
N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Pseudo Item Name Code

0000863

Related Hardware Products

Αριθμός εξαρτήματος Περιγραφή
0361-0006 Tubular Rivet
MS16535A246 Tubular Rivet

Συχνές ερωτήσεις

What is the FSCG of the NSN 5320-00-395-6512?
The FSCG of the NSN 5320-00-395-6512 is 5320
Does the NSN 5320-00-395-6512 have a Schedule B code assigned?
Yes, the Schedule B code is 7616103000
Does NSN 5320-00-395-6512 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5320-00-395-6512 contain precious materials?
Precious metal content is unknown
Does NSN 5320-00-395-6512 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5320-00-395-6512 was assigned to the Federal Catalog?
It was assigned πριν 52 χρόνια, on Fri, Apr 12, 1974