Aerospace Hardware Store

Aerospace

Hardware

4820-01-577-5154

Check Valve

Specifications, compliance details, and sourcing options for this NSN. Request a quote to confirm availability, pricing, and lead time.

Request for Quote

Send us a request for quote using the form below. Our team will promptly provide you with the latest pricing and availability details.

AS9120 ISO9001 Aviation Suppliers Association Global Shipping

Ausgewählte Teile

GD2411-7
5330-00-452-1949
Preformed Packing
GD2413-3
5330-00-453-3066
Preformed Packing
GD2414-1
5330-00-452-3348
Preformed Packing
GD2414-28
5331-00-167-6519
O-Ring
GD2415-1
5330-00-452-3338
Preformed Packing
GD2415-2
5330-00-452-3269
Preformed Packing
GD2415-3
5330-00-467-9064
Preformed Packing
GD2415-4
5331-00-167-6540
O-Ring

Need Assistance?

Our catalog is extensive, but we understand that sometimes specific needs might not be immediately available. If you could not find the exact products you were searching for, we are here to help!

Contact us directly, and our team will assist you in finding the perfect solution for your requirements.

Kontaktieren Sie uns

Certified Supplier

Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.

  • Genuine Manufacturers Parts
  • 100% Product Inspection
  • 7 Year Sales Record Retention
  • Fast On-Time Delivery
  • HAZMAT-zertifiziert
  • Global Shipping

Official Item Classification

Name
Check Valve
(NSN) Nationale Lagernummer
4820-01-577-5154
(FSG) Federal Supply Group
48 Valves
(FSC) Bundesversorgungsklassifizierung
4820 Nicht angetriebene Ventile
(INC) Artikelbezeichnung Code
05487
(FIIG) Leitfaden zur Identifizierung von Bundesartikeln
A530B0
Datum
09/09/2009 (vor 17 Jahren)

0.750 inches all ends nominal pipe size accommodated, cone flow control device, 100.0 fahrenheit 1st response maximum operating temp, 200.0 fahrenheit 2nd response maximum operating temp, spring disk loading method

Specs & Compatibility

Nominale Rohrgröße untergebracht

0.750 inches all ends

Durchflusskontrollgerät

cone

Methode zum Laden der Festplatte

spring

Maximale Betriebstemperatur

100.0 fahrenheit 1st response

Maximale Betriebstemperatur

200.0 fahrenheit 2nd response

Endproduktidentifizierung

new construction ssn774

Art der Verbindung

plain, optional end (pipe) all ends

Methode der Ventilbedienung

automatic

Verbindungsart

unthreaded internal pipe all ends

Maximaler Betriebsdruck

200.0 pounds per square inch 2nd response

Maximaler Betriebsdruck

400.0 pounds per square inch 1st response

Von der Kontrollbehörde zugewiesener Teilename

silent check valve

Besondere Merkmale

nha ventilation control unit p/n 19-87-8005; tm 56161-wc-fse-010

Material

copper alloy body

Medien, für die entwickelt wurden

water-oil-gas single response

Stilbezeichnung

straight thru

Regulatory Compliance

Precious Metals Indicator
A

Item does not contain precious metal.

Criticality Code
X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Hazardous Metals Indicator
N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Pseudo Item Name Code

0005487

Related Hardware Products

Teilenummer Beschreibung
10197 Check Valve

Häufig gestellte Fragen

What is the FSCG of the NSN 4820-01-577-5154?
The FSCG of the NSN 4820-01-577-5154 is 4820
Does the NSN 4820-01-577-5154 have a Schedule B code assigned?
Yes, the Schedule B code is 8481301090
Does NSN 4820-01-577-5154 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 4820-01-577-5154 contain precious materials?
Item does not contain precious metal.
Does NSN 4820-01-577-5154 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 4820-01-577-5154 was assigned to the Federal Catalog?
It was assigned vor 17 Jahren, on Wed, Sep 9, 2009