Aerospace Hardware Store

Aerospace

Hardware

4810-00-887-4337

Solenoid Valve

Specifications, compliance details, and sourcing options for this NSN. Request a quote to confirm availability, pricing, and lead time.

Request for Quote

Send us a request for quote using the form below. Our team will promptly provide you with the latest pricing and availability details.

AS9120 ISO9001 Aviation Suppliers Association Global Shipping

الأجزاء المميزة

HL20PB86PB-11
5320-01-398-9483
Pin-Rivet
HL20PB86PB-5-10
5320-01-398-9485
Pin-Rivet
HL20PB86PB-5-3
5320-01-396-5853
Pin-Rivet Collar
HL20PB86PB-5-5
5320-01-396-5856
Pin-Rivet Collar
HL20PB86PB-5-6
5320-01-398-9488
Pin-Rivet
HL20PB86PB-5-7
5320-01-124-3122
Pin-Rivet
HL20PB86PB-5-8
5320-01-166-2637
Pin-Rivet
HL20PB86PB-5-9
5320-01-166-2638
Pin-Rivet

Need Assistance?

Our catalog is extensive, but we understand that sometimes specific needs might not be immediately available. If you could not find the exact products you were searching for, we are here to help!

Contact us directly, and our team will assist you in finding the perfect solution for your requirements.

اتصل بنا

Certified Supplier

Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.

  • Genuine Manufacturers Parts
  • 100% Product Inspection
  • 7 Year Sales Record Retention
  • Fast On-Time Delivery
  • معتمد من المواد الخطرة
  • Global Shipping

Official Item Classification

اسم
Solenoid Valve
(NSN) رقم السهم الوطني
4810-00-887-4337
(FSG) مجموعة الإمداد الفيدرالية
48 Valves
(FSC) تصنيف الإمدادات الفيدرالية
4810 Valves Powered
(INC) اسم العنصر الكود
10998
(FIIG) دليل تحديد العناصر الفيدرالية
A046B0
تاريخ
01/01/1962 (منذ 64 سنة)

0.375 inches 1st end nominal pipe size accommodated, right-hand 1st end thread direction, piston flow control device, 3b 1st end thread class, 0.562 inches offset distance

Specs & Compatibility

Nominal Pipe Size Accommodated

0.375 inches 1st end

فئة الخيط

3b 1st end

اتجاه الخيط

right-hand 1st end

وقف التنفيذ

0.562 inches

جهاز التحكم بالتدفق

piston

العملية العادية لتحديد المواقع

open

أقصى درجة من التشغيل

160.0 fahrenheit single response

أسلوب الربط

gasket seal(boss) 1st end

التقييم الحالي في أمبس

1.500

عملية القيم المنهجية

solenoid

نوع الارتباط

threaded internal boss 1st end

الحركة

horizontal or vertical

كمية الخيوط لكل بوصة

18 1st end

الحد الأقصى للضغط التشغيلي

3000.0 pounds per square inch single response

حجم الخيط الاسمي

0.562 inches 1st end

Voltage in Volts and Current Type

18.0 dc and 30.0 dc

Nominal Outside Diameter Tube Accommod

0.375 inches 1st end

مادة

aluminum alloy body

مادة

steel corrosion resisting seat

Media for which Designed

fuel/oil, hydrocarbon single response

مُحدد الأسلوب

straight thru w/offset

مُعَيِّن سلسلة الخيوط

unf 1st end

Regulatory Compliance

Precious Metals Indicator
A

Item does not contain precious metal.

Criticality Code
X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Hazardous Metals Indicator
N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Pseudo Item Name Code

0010998

Related Hardware Products

رقم القطعة وصف
1374-598497 Solenoid Valve
668401-1 Solenoid Valve

الأسئلة الشائعة

What is the FSCG of the NSN 4810-00-887-4337?
The FSCG of the NSN 4810-00-887-4337 is 4810
Does the NSN 4810-00-887-4337 have a Schedule B code assigned?
Yes, the Schedule B code is 8481809005
Does NSN 4810-00-887-4337 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 4810-00-887-4337 contain precious materials?
Item does not contain precious metal.
Does NSN 4810-00-887-4337 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 4810-00-887-4337 was assigned to the Federal Catalog?
It was assigned منذ 64 سنة, on Mon, Jan 1, 1962