Aerospace Hardware Store

Aerospace

Hardware

4820-00-551-2955

Globe Valve

Specifications, compliance details, and sourcing options for this NSN. Request a quote to confirm availability, pricing, and lead time.

Request for Quote

Send us a request for quote using the form below. Our team will promptly provide you with the latest pricing and availability details.

AS9120 ISO9001 Aviation Suppliers Association Global Shipping

الأجزاء المميزة

060F-0002
5330-01-703-3947
Gasket
060G45-6XX
4730-01-596-4525
Sediment Strainer Element
060GR0016
4730-01-615-9194
Packing Nut
060HD1-212 ASY 0602HD-S0401216
4730-01-518-1302
Sediment Strainer
060HD2-211
4730-01-518-1303
Sediment Strainer
060KDAN-306 P/N 060-86-46
3020-01-501-7472
Gear Drive Adapter
060KDAN-306 P/N Z1006CB8
5305-01-501-2749
Hexagon Head Cap Screw
060L3332
5330-01-460-3394
Mecha Seal Replacement Parts Kit

Need Assistance?

Our catalog is extensive, but we understand that sometimes specific needs might not be immediately available. If you could not find the exact products you were searching for, we are here to help!

Contact us directly, and our team will assist you in finding the perfect solution for your requirements.

اتصل بنا

Certified Supplier

Order with confidence. We are a valued certified supplier serving customers in the military and aerospace industries.

  • Genuine Manufacturers Parts
  • 100% Product Inspection
  • 7 Year Sales Record Retention
  • Fast On-Time Delivery
  • معتمد من المواد الخطرة
  • Global Shipping

Official Item Classification

اسم
Globe Valve
(NSN) رقم السهم الوطني
4820-00-551-2955
(FSG) مجموعة الإمداد الفيدرالية
48 Valves
(FSC) تصنيف الإمدادات الفيدرالية
4820 القيم غير العاملة
(INC) اسم العنصر الكود
05485
(FIIG) دليل تحديد العناصر الفيدرالية
A046B0
تاريخ
10/22/1974 (منذ 51 سنة)

needle flow control device, inside screw bonnet type, right-hand all ends thread direction, threaded bonnet attachment method, 200.0 fahrenheit single response maximum operating temp

Specs & Compatibility

اتجاه الخيط

right-hand all ends

جهاز التحكم بالتدفق

needle

بونيت نوع

inside screw

بونيت طريقة الملحق

threaded

أقصى درجة من التشغيل

200.0 fahrenheit single response

أسلوب الربط

plain,optional end(pipe) all ends

عملية القيم المنهجية

manual

نوع الارتباط

threaded internal pipe all ends

الميزات المقدمة

bonnet packing

الحد الأقصى للضغط التشغيلي

6000.0 pounds per square inch single response

حجم الخيط الاسمي

0.500 inches all ends

الميزات الخاصة

furnished w/penton sleeve insert

مادة

steel comp 316 overall

وثيقة المواد والتصنيف

66 fed std single material response overall

Media for which Designed

water-oil-gas single response

مُحدد الأسلوب

straight thru

مُعَيِّن سلسلة الخيوط

npt all ends

Replacement For

رقم القطعة وصف
4820-00-229-8931 No Name Available 09/01/2023
4820-01-104-6335 No Name Available 11/01/1991

Regulatory Compliance

Precious Metals Indicator
U

Precious metal content is unknown

Criticality Code
X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Hazardous Metals Indicator
N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Pseudo Item Name Code

0005485

Related Hardware Products

رقم القطعة وصف
10M057 Globe Valve
1936N1314-1-2IN Globe Valve
N1314 Globe Valve
TYPE1936N13141-1-2IN Globe Valve

الأسئلة الشائعة

What is the FSCG of the NSN 4820-00-551-2955?
The FSCG of the NSN 4820-00-551-2955 is 4820
Does the NSN 4820-00-551-2955 have a Schedule B code assigned?
Yes, the Schedule B code is 8481803060
Does NSN 4820-00-551-2955 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 4820-00-551-2955 contain precious materials?
Precious metal content is unknown
Does NSN 4820-00-551-2955 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 4820-00-551-2955 was assigned to the Federal Catalog?
It was assigned منذ 51 سنة, on Tue, Oct 22, 1974